IdeCommon problems and solutions of liquid-cooled transformer

Publish Time: 2022-01-04     Origin: Site

We know that the liquid-cooled transformer is used in our lives to facilitate our production and life. We also have some problems with the liquid-cooled transformer, so the common problems and solutions of the liquid-cooled transformer what is it then? Let's take a look together next.

This is the content list:

l liquid-cooled transformer three-phase load imbalance or seasonal overload

l Poor grounding of liquid-cooled transformer

liquid-cooled transformer three-phase load imbalance or seasonal overload


The three-phase load imbalance of liquid-cooled transformer distribution transformers can be seen from the survey results. Especially in rural areas, most of the power load of liquid-cooled transformer is single-phase load, and the load changes greatly. The unbalanced load of the three phases of the cooled transformer makes the three phases unable to operate symmetrically, resulting in zero-sequence current. This on the one hand increases the loss of the liquid-cooled transformer, and on the other hand, reduces the effective capacity of the transformer. The above two conditions will cause the transformer to overheat and the insulation oil to deteriorate, which will reduce the insulation level of the liquid-cooled transformer group, and eventually cause the liquid-cooled transformer to be damaged. The following measures can be taken: investigate the load of the liquid-cooled transformer, including the load of 24 hours a day and the load of 4 seasons a year, find out the general situation of the load, and adjust the three-phase load of the liquid-cooled transformer as much as possible to make It is close to the symmetrical operation. Adjust the peak and valley time of the liquid-cooled transformer to reduce the load of the liquid-cooled transformer. At the same time, increase the capacity of the liquid-cooled transformer in time to avoid long-term overload operation of the liquid-cooled transformer.


Poor grounding of liquid-cooled transformer


The lightning protection work of liquid-cooled transformer is generally done, but there are still two problems: The lightning arrester of liquid-cooled transformer is poorly grounded. Only attach importance to the installation of lightning arresters on the high-voltage side, while ignoring the problem of installing arresters on the low-voltage side (especially in mine-prone areas). If the lightning arrester is poorly grounded and overvoltage occurs, the arrester cannot discharge the current well, which will damage the insulation of the liquid-cooled transformer. If the low-voltage site is not equipped with a lightning arrester, when the high-voltage side arrester discharges a large lightning current to the ground, the liquid-cooled transformer will produce a voltage drop at the ground position. This voltage will also act on the low-voltage while passing through the liquid-cooled transformer housing. The neutral point of the sidewinding and the low-voltage side winding is grounded through the wave impedance of the low-voltage line. The following measures can be taken to find out the poor grounding related to the arrester, and reconnect as required. Note First, connect the ground wire of the liquid-cooled transformer's arrester directly with the liquid-cooled transformer's shell and the low-voltage side neutral point, and then share the grounding device. Its grounding resistance should not exceed 4 Ω. For minefields, a set of low-voltage arresters should be added to the low-voltage side.

Zhejiang Shuntong Electric Co., Ltd. is a professional manufacturing enterprise integrating development, production, sales, and service. The above is about the common problems and solutions related to the liquid-cooled transformer. If you are interested in a liquid-cooled transformer, please contact us. Our website is www.sntoom.com. We look forward to your visit and hope to cooperate with you.

Quality-Brings you a visible future and 

an unspeakable excitement.

Electric Co., Ltd. was established in2009 , specializes in the production of various high-low-voltage equipment.

Contact

 86-577-61721053.
86-577-56848069.
     86-1336978582.
     86-15657768868.
   No.218,Liule Road,Liushi Town325604,Yueqing City,Wenzhou City,Zhejiang Province,China

We will reply asap!

Copyright ©  2025 Zhejiang Shuntong Electric Co.,Ltd.  Sitemap

We will reply asap!